NE134
www.baumer.com 15
Line 33 Input logic and switching threshold
0 * PNP Switching threshold 6V
1 NPN Switching threshold 6V
2 PNP Switching threshold 3V
3 NPN Switching threshold 3V
Line 34 Control input 1 function (assignemnt 9)
0 * PC Main counter - static reset
1 PC Main counter - edge active reset
2 PC Main counter and totalizer - Stop
3 Hold
4 Programming lock
5 Key lock
6 Print (min. impulse width 30ms)
7 Outputs P2 (P1) ON (PR_MODE inverted)
8 Outputs P2 (P1) OFF
Line 35 Min. Impulse width of control input 1
0 * 30 ms
1 100 µs
Line 36 Function control input 2 (assignment 10)
0 PC Main counter – static reset
1 PC Main counter - edge active reset
2 * PC Main counter and totalizer - Stop
3 Hold
4 Programming lock
5 Key lock
6 Print
7 Outputs P2 (P1) ON (PR_MODE inverted)
8 Outputs P2 (P1) OFF
9 ext. count input of batch counter
Line 37 Function control input 3 (assignment 11)
0 * tot totalizer – static reset
1 tot totalizer - edge active reset
2 b Batch counter – static reset
3 b Batch counter - edge active reset
4 Programming lock
5 Key lock
6 Print
7 Outputs P2 (P1) ON (PR_MODE inverted)
8 Outputs P2 (P1) OFF
9 external Count input of Batch counter
Line 38 Adoption of presets P1, P2, SC
0 * Immediately effective
1 Effective after reset
Line 40 Output logic
0 * Both outputs as normally closed
1 P1 as normally open, P2 as normally closed
2 P1 as normally closed, P2 as normally open
3 Both outputs as normally open
Line 41 Output time P1
0.01 Minimum signal duration
0.25 * Default
99.99 Maximum signal duration
Latch Latch (by pressing the C key)
Line 42 Output time P2
0.01 Minimum signal duration
0.25 * Default
99.99 Maximum signal duration
Latch latch (by pressing the C key)
Line 50 Code settings
0000 * Code not active
:
9999
Line 51 Baudrate
0 * 4800 Baud
1 2400 Baud
2 1200 Baud
3 600 Baud
Line 52 Parity
0 * Even Parity
1 Odd Parity
2 No Parity
Line 53 Stop bits
0 * 1 Stop bit
1 2 Stop bits
Line 54 Address
00 * Default
00 Min.
99 Max.