www.baumer.com 7
9. Programming plan
Parameter enabled for programming
Subtracting (reset to P2)
Subtracting; but output contact at SC, auto-
matic reset at 0
Decimal point in PC, P1, P2, tot, SC
Track A UP/DOWN signal at B where required
Track A 90° B Single evaluation
Track A 90° B Double evaluation
Track A 90° B Quadruple evaluation
Same as 6 but with start and stop
PNP Trigger threshold 6 V
NPN Trigger threshold 6 V
PNP Trigger threshold 3 V
NPN Trigger threshold 3 V
Functionality control input 1 (terminal 9)
Reset totalizer edge-triggered
Outputs IN (P1,P2) and reset fl.
Reaction time of control input 1
Functionality control input 2 (terminal 10)
Reset totalizer edge-active
Adoption of presets P1,P2,SC
Output logic of digital outputs
Both outputs normally closed
P1 normally open, P2 normally closed
P1 normally closed, P2 normally open
Both outputs normally open