NE218
www.baumer.com 14
9. Parameterization plan
Zl 11-17 Status for lines 1-7
0 Parameter change enabled
1 Parameter lock (entry,clearing)
2 Skip parameter
Line 22 Operating modes
0 Step preset
1 Main preset
2 Parallel comparison
3 P1-dragged preset
Line 24 Decimal point
0 No decimal point
1 00000.0
2 0000.00
3 000.000
4 00.0000
Line 25 Count mode
0 Track A resp. UP/DOWN-signal on track B
1 Subtracting (A-B)
2 Adding (A+B)
3 Track A 90° B single evaluation
4 Track A 90° B double evaluation
5 Track A 90° B four times evaluation
Line 26 Frequency main counter track A
0 10 kHz
1 25 Hz
2 3 Hz
Line 27 Frequency main counter track B
0 10 kHz
1 25 Hz
2 3 Hz
Line 28 Input logic
0 PNP - Trigger threshold 10V
1 NPN - Trigger threshold 10V
2 PNP - Trigger threshold 5V
3 NPN - Trigger threshold 5V
4 PNP - Trigger threshold 2,5V
5 NPN - Trigger threshold 2,5V
Line 29 Reset main counter (control input 1)
0 Automated reset and ext. static
1 Automated reset and ext. differntiated
2 Extern static
3 Extern differentiated
4 Extern with "Start-functionality"
Line 31 Functionality control input 2
0 Stop
1 Hold
2 Keylock
3 Hour counter on/off
4 Offset
5 Print (only with interface)
Line 33 Digital output logic
0 Both outputs normally closed
1 P1 Normally open, P2 Normally closed
2 P1 Normally closed, P2 Normally open
3 Both outputs Normally open
Line 35 Latch signal duration P1
0.25 Default
0.01 Min.
99.99 Max.
Line 36 Latch signal duration P2
0.25 Default
0.01 Min.
99.99 Max.
Line 37 Preset P1, P2 adoption
0 Immediately effective
1 After reset
Line 38 Counting range P1,P2 and SC
0 Only positive
1 Positive and negative
Line 39 Function key assignment
0 Not operational
1 XP
2 P1
3 P2
4 SC
5
Σ
6
§
7 SF
Line 40 Code
0000 Code not active
:
9999
Line 41 Functionality batch counter
0 Totalizer
1 When achieving P2
Line 42 Multiplier batch counter (Line 41=1)
1 Default
0 Min.
999 Max.
Line 43 Offset
0 No offset
:
999999 Max. offset
Line 44 Power loss warning
0 No warning
1 warning (display flashing)
Line 51 Baudrate
0 4800 Baud
1 2400 Baud
2 1200 Baud
3 600 Baud
Line 52 Parity
0 Even Parity
1 Odd Parity
2 No Parity
Line 53 Stoppbits
0 1 Stoppbit
1 2 Stoppbits
Line 54 Adresse
00 Default
00 Min.
99 Max.
Line 55 Output assignment via interface
Line 31=5
0 Displayed value
1 XP
2 P1
3 P2
4 SC
5
Σ
6
§
7 SF
Line 56 RS422: connections TxD+ , TxD-
0 In transmission direction during trans-
m
ission, in receiving direction upon
receipt
1 Ever in transmission direction