Page 3 Design and specifications subject to change without notice
Installation Manualwww.baumer.com
Electrical Installation - LKP100 Amplifier for In-head Mounting
Sensibility Connection Typical application
20 KOhm
Terminal S connected to + (plus) Water
2 KOhm Terminal S not connected Beer, juice, youghurt
200 Ohm
Terminal S connected to - (minus) Acid, Alkalis
1: Brown
2: White
3: Blue
4: Black
1
2
3
4
5
6
S
Input
Gnd
18...36 Vdc
1
4
2
3
S
+
+
-
-
1
2
3
4
5
6
S
Gnd
18...36 Vdc
1
4
2
3
S
+
-
Output load
max. 50 mA
LED
LED
0 mA
Output load
max. 50 mA
50 mA
50 mA
0 mA
Input
Note: Terminal S is for local or remote setting of the sensibility.
+
-
DNGA230100
Electrical Installation - DNGA 230100
Refer to Installation manual 5511-507.
M12 Plug
ø7
ø44
33